Military-Grade Waterproof Test Chamber
Military-grade waterproof test chamber simulates dripping, spraying and high-pressure water jets to test the sealing performance of automotive and electrical components.
Advantages of Haida Test Chambers
Haida equipment military-grade waterproof test chamber performs dripping, water-spraying and high-pressure water-jet tests to verify waterproof performance of various components.
Applicable samples include vehicle lamps, meters, seat adjusters, electrical dust boots, lamps, steering components, door locks, connectors, etc. It verifies functional performance and safety after water exposure.
Specifications
Basic Data
| Model | HD-E710-7 |
|---|---|
| Product Name | Military-Grade Waterproof Test Chamber (Color Touch-Screen Model) |
| Sample Restrictions | Samples below are NOT allowed for testing:
|
| Volume, Dimension & Weight | |
| Inner Chamber Size (mm) | 3400×1500×1500 (W×D×H) mm |
| Outer Chamber Size (mm) | 6000×1700×6200 (W×D×H) mm (subject to actual dimensions) |
| Door Opening Size (mm) | 1000×1100 (W×H) mm |
| Turntable | SUS304 stainless steel hollow turntable, Φ600 mm.
Rotating speed: 1~15 R.P.M adjustable; load capacity: 100 kg |
| Power & Power-Supply Requirement | |
| Power Supply | AC (380±10)V, 50 Hz, 3-Phase; Total Power:45 KW |
| Power Supply Condition | Protective ground resistance less than 4Ω. Buyer shall install independent air-switch for this equipment on-site. Knife-switch or power socket shall NOT be used. |
| Performance Indicators | |
| Applicable Test Standards | GJB-150.8A / MIL-STD-810G Method 506.6, Procedure I, Procedure II & Procedure III |
| Test Conditions | 1. Procedure I- Rain and Blowing-Rain Test (shared drip tray with Procedure III). 1 set of 1000×1000 mm drip water tank 0.5 mm nozzles, droplet diameter 0.5~4.5 mm, total 1521 pcs.Micro-computer segmented adjustable flow control system ×1 set. Water-temperature sensor, adjustable water temperature.Two sets of 32-inch fans, horizontal circulating air, wind speed up to 18 m/s, variable-frequency adjustable. Horizontal & 45°-angle blowing rain. Rainfall intensity: 1.7 mm/min. Distance from drip tray to turntable: 4200 mm |
| 2. Procedure II- Intensified Water-Spray Test. 2 sets of 710×710 mm spray grids (top & side each one set) Water pressure: 276 kPa Sensor for sample temperature & water temperature; adjustable water temperature Nozzle-to-sample distance: 48 cm, manually adjustable |
|
| 3. Procedure III- Heavy Drip Test (shared drip tray with Procedure I). Drip rate: 140 L/m²/Hr or 280 L/m²/Hr 1 set of 1000×1000 mm drip water tank 0.5 mm nozzles, droplet diameter 0.5-4.5 mm, total 1521 pcs Micro-computer segmented adjustable flow-control system ×1 set Distance from drip tray to turntable: 4200 mm |
|
| 8.Structural Features | |
| 8.1 Chamber Structure | Interior: SUS#304 stainless steel plate
Exterior: SECC steel plate with powder-coated finish Reinforced glass observation window: 400×600 mm Movable casters + fixed leveling feet Aluminum-alloy drip-tank mounting frame 4 pcs large-flow solenoid valves Precision removable filter screen Low-water-level alarm device, overflow pipe |
| 8.2 Motor, Pump & Fan | 1.Variable-frequency booster pump motor: 3Hp ×1 set
2.Turntable rotation motor with reducer & digital tachometer ×1 set, speed 1-15 rpm 3.Vacuum pump: 1HP ×1 unit 4.Φ30-inch stainless-steel fan ×1 unit 5.TECO direct-drive motor ×1 unit |
| 8.3 Water Tank | Internal circulating water tank for water-saving; high-density filter cartridge filter |
| 8.4 Circuit & Control System | Main controller: Kunlun Tongtai LCD touch-screen HMI
PLC integrated HMI controller Fault events recorded & displayed in text for easy maintenance Touch-screen setting & digital readout; all test parameters auto-locked by micro-processor Digital auto-control; auto-run upon selecting test conditions Start-stop time programmable; easy operation Delta 1.75 kW inverter, 0-60 Hz ×1 set Modbus TCP/IP, RJ485 communication port for external connection & real-time monitoring via VNC software |
| 8.5 Refrigeration System | High-efficiency refrigeration compressor
Refrigerant: R404a All piping tested by nitrogen pressurization for 48 hours for leakage check Independent heating & cooling circuits Inner-helix K-TYPE titanium refrigerant tube Corrugated fin-type forced-air condenser Sloped FIN-TUBE evaporator Imported solenoid valves, dry filter, expansion valves and other refrigeration components All refrigeration logic controlled by micro-processor for high efficiency & energy-saving Bare stainless-steel electric heating tube SSR+PID micro-processor temperature controller |
| 8.6 Flowmeter, Anemometer & Negative-Pressure Module | 1.Hand-held anemometer ×1 unit
2.Glass rotameter ×2 units 3.Mindman two-stage precision filter cup ×1 set 4.Imported Yellow-jacket vacuum hose with connectors ×1 set 5.Vacuum flow regulating system (with negative-pressure adjustment & dual-stage filter) |
| 9.Electrical Control Cabinet | Power distribution board, cooling fan, over-temperature protector. Control cabinet is isolated from valve compartment. |
| 10.Power Cable | Power cable & main power switch located at rear of electrical cabinet. |
| 11.Operation Mode | Programmable running & rest time, total test time configurable. |
| 12Controller | OMRON E5CC digital temperature controller for chamber temperature & humidity display. |
| 13.Display Resolution | Flow: 0.1 L/hr |
| 14.Timer | Run/rest time in min/sec; max total test time 999 hours. |
| 15.Other Accessories | 3-meter 5-core (3-phase-5-wire) power cable ×1 piece |
| 16.Safety Protection Devices | |
| 16.1 Door-Open Protection | Safety switch for chamber door opening |
| 16.2 Overload Protection | Pump motor & turntable overload protection |
| 16.3 Power Section | EU-standard power switch |
| 16.4 Indicator Light | Tri-color status indicator lamp |
| 16.5 Transportation | Integrated unit, packed for freight delivery to site |
| 17.Auxiliary Items (to be prepared by Buyer) | |
| 17.1 Ambient Conditions | Ambient temperature: 5℃~30℃
Relative humidity: ≤85%RH Atmospheric pressure: 86 kPa~106 kPa |
| 17.2 Compressed-Air Supply | Air consumption 2 m³/h. Buyer shall supply dry, oil-free filtered compressed air at 0.4-0.8 MPa. |
| 17.3 Installation Site Requirements | Level floor, well-ventilated; free of flammable, explosive or corrosive gas/dust; away from strong electromagnetic radiation.
Floor load capacity ≥ 600 kg/m². Reserve maintenance clearance around unit. A ≥ 400 mm; B ≥ 1000 mm; C ≥ 1000 mm |
| 17.4 Installation & Commissioning | On-site execution (not only verbal guidance). Commissioning completed within one month after buyer’s notification upon machine arrival, following agreed schedule.
Written pre-notification to buyer for required site utilities before commissioning. |
| 17.5 Operation & Maintenance Training | Training conducted during final acceptance at buyer’s premises.
Contents: equipment principle, operating procedures & precautions; system software & data processing; electrical-mechanical maintenance; emergency handling & basic troubleshooting. |
| 17.6 After-Sales Service | One-year warranty period. Free software maintenance & upgrade within warranty.
Response within 24 hours upon buyer’s fault notification. Spare-parts supply & repair service available after warranty expiration. |
| 17.7 Acceptance | Acceptance includes Pre-Acceptance and Final Acceptance.
Pre-Acceptance: Performed at manufacturer’s workshop before shipment, inspecting against technical specification. Shipment released only after buyer approves pre-acceptance result. Final Acceptance: Carried out at buyer’s site after 100-hours continuous normal operation. Third-party inspection report (issued by national environmental-test-equipment authority) can be arranged at buyer’s cost. If first acceptance fails, re-inspection cost shall be borne by supplier. |
| 18.Factory-Supplied Documents & Spare Parts | Operation & maintenance manual and circuit diagram ×1 set
Factory test report ×1 copy Product warranty certificate ×1 copy 5A fuse ×2 pcs Spare filter cartridges ×4 pcs |
Performance Data
Want to know more? Talk to an expert!
Leave a message and a specialist will get back to you.